What Are the Different Alarms?
A reference for the alarms configured on Titan Logix transmitters — what sets each one, the condition it reports, and its default control relay behavior.
| Alarm | Alarm Set By | Condition | Control Relay Assignments |
|---|---|---|---|
| Spill | Transmitter | Tank volume is in overfill state | Programmable* |
| High-High (HH) | Transmitter | The maximum safe volume of the tank (set by the user) | Programmable* |
| Fill | FINCH II | User determined tank levels for use when filling the tank. | Programmable* |
| Fall | FINCH II | User determined tank levels for use when draining the tank. | Programmable* |
| Fail | FINCH II and TD100 Transmitter | System failures such as internal transmitter errors, probe faults or loss of communications are reported by the Spill/Fail Relay and shown on the FINCH II display | Programmable* |
| 2 Lo | Factory (Pre-Set) | Tank volume is less than 2.5" from the top of the shorting block (too low for correct readings) | No Relay - Factory Pre-Set |