Configuring My FINCH II Display Using SensorLink
The FINCH II display is initially configured with factory default settings tailored for the most typical tank truck and trailer applications. There are a few common reasons you may need to change that configuration.
When You'd Need to Reconfigure
Below are the three main reasons why you would need to configure your FINCH display using SensorLink.
First-Time FINCH II-6W Setup
Did you just purchase a FINCH II-6W? Before using our FINCH II-6W displays, it is mandatory to complete the configuration process.
Firmware Updates
New features for Titan Logix's hardware can be pushed out through firmware updates. To ensure optimal performance and functionality of your system, it is essential to update to the latest firmware version whenever one becomes available.
Customizing Alarm Relays
You are able to customize the factory default settings for specific alarms that are connected to one of the four relays. The FINCH II configuration is set at the factory for the most common tank truck and trailer installations, but it can be customized to suit specialized applications.
What Do You Need?
All that's required to configure your FINCH II display is a computer with the latest version of SensorLink installed, a programming kit, and an internet connection for downloading any new firmware file.
Programming Kit Components
The following cables are used to connect your computer to your FINCH display.
- USB to RS232 Converter
- RS232 Cable
- Power Cable
- AC Power Adapter
The FINCH display needs to be powered on in order to program or configure it. You can do this one of two ways:
- From the Vehicle — using the vehicle battery power from your truck. This is best when the FINCH II display is already mounted on your unit and you do not want to take it off. This only requires cables 1 and 2.
- From a Power Outlet — using cables 3 and 4 to connect to a power outlet from a bench setup.
From the Vehicle
Below is an image showing the FINCH II display using the vehicle battery power to configure the display. You do not need cables 3 or 4 from the programming cables listed above if this is how you will be connecting to the FINCH.
From a Power Outlet
Below is an image showing the FINCH II display using the AC Power Adapter to power the display.
When using the AC Power Adapter for configuration and firmware updates, make sure to disconnect all devices connected to the Pump Relay, Horn Relay, Light Relay and Engine Relay to prevent damage to the AC Power Adapter.
Full Configuration Guide
Download the complete FINCH II configuration guide for a full walkthrough of the setup process.