Strapping table files may be created from scratch using the Portal. These files are then available for mechanics to program transmitters and for administrators to import/export them.

Create and upload a strapping table

  1. Step 1

    Log into your Titan Portal account.

    Titan Portal screenshot — step 1
  2. Step 2

    In the CORE menu, click Transmitter Configuration.

    Titan Portal screenshot — step 2
  3. Step 3

    Click the New Strapping Table button.

    Titan Portal screenshot — step 3
  4. Step 4

    Click Create from scratch.

    Titan Portal screenshot — step 4
  5. Step 5

    Enter the new strapping table file name.

    Titan Portal screenshot — step 5
  6. Step 6

    The 1st entry of 0 depth and 0 volume have already been filled in. All strapping tables must begin with 0 and 0.

  7. Step 7

    Enter the depth and volume values from the depth chart provided by the customer. Click the Add Row button to keep adding rows until all the values have been entered.

    Titan Portal screenshot — step 7
  8. Step 8

    Set the Probe Type, Detection Mode, Depth Units and Volume Units. Click the Next button to continue.

    Titan Portal screenshot — step 8
  9. Step 9

    Set or review the Spill alarm options and then enter HH alarm volume or depth. Click the right arrow next to Alarm Settings to continue.

    Titan Portal screenshot — step 9
  10. Step 10

    Enter the Offset Measurement values for Tank Thickness and Probe Offset. Click the right arrow next to Offset Measurement to continue.

    Titan Portal screenshot — step 10
  11. Step 11

    Set the Display Decimal and Decimal Shift if required. Click the right arrow next to FINCH Display Settings to continue.

    Titan Portal screenshot — step 11
  12. Step 12

    Enter the Sump depth if required. Click the right arrow next to Sump Settings to continue.

    Titan Portal screenshot — step 12
  13. Step 13

    Set the 4-20mA settings if required. Click the right arrow next to 4-20mA Settings to continue.

    Titan Portal screenshot — step 13
  14. Step 14

    This screen confirms that all settings have been completed or reviewed. Click the Close button.

    Titan Portal screenshot — step 14
  15. Step 15

    Click the Save button in the lower right corner of the screen to continue.

    Titan Portal screenshot — step 15
  16. Step 16

    The newly created strapping table file is now in the list of files.