FINCH II Fill & Fall Alarm Settings

FINCH II Fill & Fall Alarm Settings

The Fill Alarm

FINCH II display showing Fill alarm

Purpose

  • Fill alarm allows the operator to set a warning at a predetermined volume while loading.
  • Used to stop loading at a predetermined volume or warn of the approaching High-High alarm at the maximum safe volume.
Setting the Fill alarm on the FINCH II display

Fill Alarm Setting

  • While in Monitor or Display mode:
    • Select the compartment for the Fill alarm setting.
    • Press and hold the UP button for more than 2 seconds and then release the button.
  • "Fill" flashes 3 times.
  • Use the UP and DWN buttons to set the Fill alarm volume.
    • Momentary press changes the volume by 1 unit.
    • Press and hold to rapidly change the volume.
    • No button press for 5 seconds ends the Fill alarm setting.
FINCH II display Fill alarm acknowledge

Fill Alarm Acknowledge

  • The active Fill alarm displays a flashing "FILL" and the current volume.
  • Clear the alarm by pressing the ACK button.

The Fall Alarm

FINCH II display showing Fall alarm

Purpose

  • Fall alarm allows the operator to set a warning at a predetermined volume while unloading.
  • Used to stop unloading at a predetermined volume or warn of the approaching minimum safe volume.
Setting the Fall alarm on the FINCH II display

Fall Alarm Setting

  • While in Monitor or Display mode:
    • Select the compartment for the Fall alarm setting.
    • Press and hold the DWN button for more than 2 seconds and then release the button.
  • "FALL" flashes 3 times.
  • Use the UP and DWN buttons to set the Fall alarm volume.
    • Momentary press changes the volume by 1 unit.
    • Press and hold to rapidly change the volume.
    • No button press for 5 seconds ends the Fall alarm setting.
FINCH II display Fall alarm acknowledge

Fall Alarm Acknowledge

  • The active Fall alarm displays a flashing "FALL" and the current volume.
  • Clear the alarm by pressing the ACK button.