Does the TD100 Transmitter Need to be Calibrated?

The TD100 Transmitter does not require periodic calibration or maintenance. It is calibrated at the factory and is self-compensating while in operation.

Note:

For the TD80, it was recommended to calibrate your truck seasonally, in the summer and winter to maintain accuracy. However, this is NOT required for the TD100.

For TD100, the calibration process is required only once when the transmitter is first installed. That calibrates the transmitter for small differences between the SensorLink-programmed Total Offset (Offset Measurement) value and the actual height above the tank. Additional adjustments is not required again while the transmitter is in service.

The Total Offset value tells the TD100 Transmitter how high it is mounted above the tank. The actual value may be slightly different. Offset Calibration ensures the best possible measurement accuracy.

If the transmitter is replaced, you will need to complete this process for the new transmitter.

 